Bomara Home » Server Technology » Smart IP PDU » Smart CS-54VD/VY: 50/60A 3 phase 42XC13 & 12xC19

 Smart CS-54VD/VY: 50/60A 3 phase 42XC13 & 12xC19
  Three Phase Smart Power Control via IP, 54 mixed outlets, LED input current displays, branch circuit protection and IP monitoring; high-density.


CS-54V_masterCS-54V_link



  • Description
  • Specifications
  • Gallery

The three phase CS-54VD/VY Smart Cabinet Distribution Unit (CDU) provides reliable power distribution for high density applications such as blade server clusters that require 3-Phase, 50-Amp or 60-Amp power. The Smart CDU provides reliable power distribution combined with local and remote power monitoring and environmental monitoring via IP. Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds.

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. The Sentry PDU product family uniquely meets these demands.

The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDU True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

The CDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes circuit breakers as an Overcurrent Protection Device (OCPD).  Now you can safely run 60-amp power drops to your server cabinet where individual outlet receptacles have lower output ratings (i.e., 20-amps).



Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet(individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.


Sentry  Cabinet PDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord** Outlets Dimensions
(L x W x D)
Sentry Smart CS-54VDY 50A/60A CDU Specifications
CS-54VDX413C6-017
CL-54VDX413C6-017*
3-Phase Delta,
240V
50/60Hz
60A IEC Blue 9hr 3P+G Plug, 10'(3m), Bottom Cord Entry (42) IEC 60320/C13
(12) IEC 60320/ C19
69.0 x 3.5 x 3.5 in.
(1753 x 89 x 89 mm)
CS-54VDV413C6-017
CL-54VDV413C6-017*
3-Phase Delta, 240V
50/60Hz
50A CS8365 Plug, Bottom Cord Entry (42) IEC 60320/C13
(12) IEC 60320/ C19
69.0 x 3.5 x 3.5 in.
(1753 x 89 x 89 mm)
CS-54VYY413C6-017
CL-54VYY413C6-017*
3-Phase Wye, 
208V
50/60Hz
60A IEC Blue 9hr 3P+N+G Plug, 10'(3m), Bottom Cord Entry (42) IEC 60320/C13
(12) IEC 60320/ C19
69.0 x 3.5 x 3.5 in.
(1753 x 89 x 89 mm)
* CL refers to the Expansion Module
**Click here to view additional information on Power Cords and Cables
Additional Features and Specifications
Standards
> cTUVus and cULus, UL 60950-1-2007
> CAN/CSA 22.2 No. 60950-1:2007
> FCC Class A, Part 15
> EMC-EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> SNMPv2 and v3
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)
> IPv6

Branch Circuit Protection

> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe 
    - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) > Environmental Monitor - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital converter. Includes (1) temperature/humidity probe with unit. Sentry Power Manager: - Monitor and Manage multiple Sentry CDU's- Monitor and Manage all alarm conditions- Reporting and Trending- Group or Cluster outlets for reboot and power information- Optional Appliance or virtual version- SPM v5.1+ is VMware READY


Additional Ordering Information


Part Number Input Output
Master Expansion Rating, North America Input Type Output Rating North America Outlet: North America Outlet Type Branch Circuit: North America/GS Phase: North America/GS
CS-54VDX413C6-017 CL-54VDX413C6-017 240V 3W+PE, 50/60Hz; 48A IEC 60309 240V, 50/60Hz; <=83.1A 12xC19 <= 16A each, 42xC13 <= 12A each IEC 60320 C13 and C19 XY1, XY2, YZ1, YZ2, ZX1, ZX2 <= 20A XY, YZ, ZX <= 27.7A
CS-54VDV413C6-017 CL-54VDV413C6-017 240V 3W+PE, 50/60Hz; 40A CS8365C 240V, 50/60Hz; <=69.3A 12xC19 <= 16A each, 42xC13 <= 12A each IEC 60320 C13 and C19 XY1, XY2, YZ1, YZ2, ZX1, ZX2 <= 20A XY, YZ, ZX <= 23.1A
CS-54VYY413C6-017 CL-54VYY413C6-017 120/208V 3W+N+PE, 50/60Hz; 48A IEC 60309 208V, 50/60Hz; <=83.1A 12xC19 <= 16A each, 42xC13 <= 12A each IEC 60320 C13 and C19 XY1, XY2, YZ1, YZ2, ZX1, ZX2 <= 20A XY, YZ, ZX <= 27.7A
CS-54VDV413C6-017/GA   240V 3W+PE, 50/60Hz; 40A CS8365C 240V, 50/60Hz; <=69.3A 12xC19 <= 16A each, 42xC13 <= 12A each IEC 60320 C13 and C19 XY1, XY2, YZ1, YZ2, ZX1, ZX2 <= 20A XY, YZ, ZX <= 23.1A
CS-54VDV413C6-017/GB   240V 3W+PE, 50/60Hz; 40A CS8365C 240V, 50/60Hz; <=69.3A 12xC19 <= 16A each, 42xC13 <= 12A each IEC 60320 C13 and C19 XY1, XY2, YZ1, YZ2, ZX1, ZX2 <= 20A XY, YZ, ZX <= 23.1A

 