Bomara Home » Server Technology » Smart IP PDU » Smart CS-6H5 415V 30A 3Ph 6xL6-30R with PIPS:

 Smart CS-6H5: 415V 30A 3 phase 6xL6-30R with PIPS
  3 Phase 415V powered CDU with NEMA locking outlets for high density applications.


CS-6H54454B4_frontCS-6H54454B4_back



  • Description
  • Specifications
  • Gallery

The three phase Sentry CS-6H5 products provide a 415V powered solution with NEMA Locking outlets for high density applications found in data center cabinets. Smart Cabinet Distribution Units (CDU) provide reliable 3-phase power distribution combined with local and remote power monitoring and environmental monitoring via IP. Use the network interface to view power, temperature, and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds. 

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet rack PDU. The Sentry cabinet PDU product family uniquely meets these demands.

This Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.

This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.

The PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes circuit breakers (UL-489 rated circuit breakers) as an Overcurrent Protection Device (OCPD). 



Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

 


Sentry  Cabinet PDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord** Outlets Dimensions
(L x W x D)
CS-6H5 - 3Ph 415V
CS-6H54454B4
CL-6H54454B4*
240/415V 3-Phase Wye, 50/60 Hz 30A IEC Red 6hr 3P+N+G Plug, 10'(3m) Cord (6) NEMA L6-30R 3.50"x17.00"x10.00"
(89x432x254mm)
CS-6H5Z454B4
CL-6H5Z454B4*
240/415V 3-Phase Wye, 50/60 Hz 30A NEMA L22-30P Plug, 10'(3m) Cord (6) NEMA L6-30R 3.50"x17.00"x10.00"
(89x432x254mm)
*CL refers to the Expansion Module
**Click here to view additional information on Power Cords and Cables


  Additional Ordering Information


Part Number Input Output
Master Expansion Rating, North America Input Type Output Rating North America Outlet: North America Outlet Type Branch Circuit: North America Phase: North America
CS-6H52454B4 CL-6H52454B4 240V/415V 3W+N+PE, 50/60Hz; 16A NEMA L22-20P 240V, 50/60Hz; <=48A 6xNEMA L6-30R <= 16A each NEMA L6-30R L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <= 16A
CS-6H53454B4 CL-6H53454B4 240V/415V 3W+N+PE, 50/60Hz; 16A IEC 60309 16A 240V, 50/60Hz; <=48A 6xNEMA L6-30R <= 16A each NEMA L6-30R L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <= 16A
CS-6H54454B4 CL-6H54454B4 240V/415V 3W+N+PE, 50/60Hz; 24A IEC 60309 24A 240V, 50/60Hz; <=72A 6xNEMA L6-30R <= 24A each NEMA L6-30R L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <= 24A
CS-6H5Z454B4 CL-6H5Z454B4 240V/415V 3W+N+PE, 50/60Hz; 24A NEMA L22-30P 240V, 50/60Hz; <=72A 6xNEMA L6-30R <= 24A each NEMA L6-30R L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <= 24A

Part Number Description
CS-6H5Z452B4 Smart CDU, 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 240/415V 3-Phase Wye 30A, 10 ft (3 m) Cord, NEMA L22-30P Plug, 30 A Circuit Breakers, 2 x Temperature/Humidity Sensor Capable
CS-6HYM423D6 Smart CDU, 1U, 6 x C19 Outlets, 3 LED Input Amp Meters, 208V 3-Phase Wye 30A, 10 ft (3 m) Cord, NEMA L21-30Pplug, (2)Temperature/Humidity Sensor Capable, Circuit Breakers, NEMA 5-20R Utility Outlet



  Additional Features and Specifications

Standards
> cTUVus - UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> FCC Class A, Part 15
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection

> Compliant to UL 60905-1

Accessories 
> EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
> EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
> Sentry Power Manager (SPM)

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification:

View Full Site View Mobile Optimized