Server Technology » HDOT (High Density Outlet Technology) Units » CS42CS-2/E

 Server Technology HDOT CS42CS-2/E 208V 20/30A with PIPS:
      42 HDOT IEC C13 Outlets 208V 20/30A with PIPS

Allows IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet.

HDOT (High Density Outlet Technology)Linkable-units-1IP


Description:

The Server Technology Smart CDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides highly-accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart “Master” CDU can be connected to the Smart “Link” CDU to extend the network access to the redundant or secondary power feed.

HDOT (High Density Outlet Technology)
The highest possible outlet density available in a network connected configurable PDU. Up to 42 C13’s in a 42U high by 1U wide device. Additional features include high native cord retention that eliminates the need for custom and costly ancillary locking cord devices. Manufactured with robust high temperature materials carrying a UL94 V-0 ame rating makes these outlets ideally suited for harsh data center environments.



  • Ordering Information
  • Features & Benefits
  • Specifications
  • Drawing


CS42CS-2/E Ordering Information:

Sentry  CDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord Outlets Dimensions
(L x W x D)
CS39CS-5 415V 3-Phase 20/30A with PIPS
CS42CS-2ABA2S000
CL42CS-2ABA2S000*
208-240V L-L Nominal, 
50/60Hz
 ≤16A
(20 peak)
IEC 60320 / C20 (42) IEC 60320/C13 69.0 x 1.75 x 2.25 in.
(1753 x 45 x 58 mm)
CS42CS-2CBA2S000
CL42CS-2CBA2S000*
208-240V L-L Nominal,
50/60Hz
≤24A
(30 peak)
NEMA L6-30P, 10ft,
3-C, 10AWG
(42) IEC 60320/C13 69.0 x 1.75 x 2.25 in.
(1753 x 45 x 58 mm)
CS42CS-EABA2S000
CL42CS-EABA2S000*
220-240V L-N Nominal,
50/60Hz
≤16A IEC 60320 / C20 (42) IEC 60320/C13 69.0 x 1.75 x 2.25 in.
(1753 x 45 x 58 mm)
CS42CS-EPBA2S000
CL42CS-EPBA2S000*
220-240V L-N Nominal,
50/60Hz
≤32A IEC 60309 6hr 2P+PE Blue,
3m, H05VV-F, 4.0mm2
(42) IEC 60320/C13 69.0 x 1.75 x 2.25 in.
(1753 x 45 x 58 mm)
* CL part numbers refer to the Expansion CDU


CS42CS-2/E Features & Benefits:

High Density Power Distribution
The Server Technology Smart CDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides highly-accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart “Master” CDU can be connected to the Smart “Link” CDU to extend the network access to the redundant or secondary power feed.

  • High Density:Single-power input feed; (42) C13 outlets per enclosure
  • Power Distribution: : 208V-240V, 16A, 20A, 30A, or 32A power input options.
  • Input Current Monitor: Precisely measure the aggregate current draw (in amps). On site verification of the input current with the LED digital display. Remote verification via web browser or serial screen.
  • IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, RADIUS, TACACS and RS-232 access
  • Alerts: Provide automated SNMP-based alarms or email alerts for power and environmental conditions
  • Environmental Monitoring: Each Smart CDU supports two external temperature & humidity probes and reports conditions through the user interface without the need for additional IP addresses
  • Add an Expansion Module: Connect the Smart Expansion CDU (CL) to a Master unit (CS) for power monitoring of separate power circuits from a single IP address

Additional Benefits:

branch-circuit-protection Branch Circuit Protection
The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections
• UL-489 rated circuit breakers
per-input-power-sensing PIPS - Per Input Power Sensing
Accurately measures Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.
temperature-and-humidity Temperature and Humidity
The Smart CDU supports two external 10’ (3m) probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alerts or email notifications when conditions exceed defined thresholds.
linking-for-smart-cdu Linking for Smart CDU (Expansion Modules)
The Smart CDU family has the capability to daisy chain units together. The Expansion Module provides the ability to link two power circuits under one IP address.
high-density-outlet-technology High Density Outlet Technology
The highest possible outlet density available in a network connected PDU. Up to 42 C13’s in a 42U high by 1U wide device.
locking-outlets Locking Outlets
All receptacles are fully compatible with Server Technology's LockedIn power cords (supplied separately).
power-pivot Power Pivot
A 90 degree rotatable power cord makes it the ultimate PDU for multiple racks and multiple facilities with overhead power or raised floor.
autoflip-current-display Autoflip Current Display
Exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase for simple load balancing.


CS42CS-2/E Specifications:

Standards
• cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07
• TUVGS Mark to EN 60950-1:2006 + A11
• EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
• FCC Class A, Part 15
• CE Mark
• RoHS/WEEE

Communications
• 10/100 Mbps Ethernet (RJ-45 connector)
• RS-232 serial (RJ-45 connector)
• Two (2) temperature/humidity sensor inputs (4P4C)
• Link port (RJ-12)
• Web-browser GUI and command-line-interface (CLI)
HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet, SNMPv2c and v3 (GET,
SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS

Branch Circuit Protection
• UL489 compliant circuit breakers, 2-pole, 20A
• Two (2) branches
• Current Rating: ≤ 16A
• Voltage Rating: 208V-240V nominal, 50/60Hz

Accessories
• EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
• EMCU-1-1B Environmental Monitor adding:
     -Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
     -One (1) EMWS-1-1 water sensor port (probe sold separately)
     -Four (4) dry contact (NO/NC) monitoring points
     -One (1) 8-bit analog-to-digital converter (0 to 5VDC)
• SPM (Sentry Power Manager):
     -Monitor and manage multiple PDUs from a single point
     -Monitor and manage alarm conditions
     -Create reports and trends on stored data
     -Analyze power usage per phase
     -Optional appliance or virtual version
     -VMware Ready
• Device / Output Locking Power Cords
     -Multiple options available
     -Contact Server Technology for details.
• Mounting Brackets
     -Buttons (KIT-0020) included for tool-less mounting.

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

 



CS42CS-2/E Drawing: