CSG-24VD/VY 50/60A 12xC13 & 12xC19 with PIPSThe Smart Cabinet Power Distribution Units (CDU) provide reliable power distribution combined with local and remote power monitoring and environmental monitoring via IP. Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds. Sentry POPS (Per Outlet Power Sensing) combines all of the features and functions of a Smart CDU with the ability to provide power monitoring per an individual outlet/device. Power information per individual outlet/device includes current, voltage, power (kW), apparent power, crest factor, and power factor. Using out grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet.

Key Features

Technical Specifications

Model
Available Input
Voltages
Amperage
Available Input
Cord**
Outlets
Dimensions
(L x W x D)
CSG-24VDX415A9
Replaced by C2SG36CE-DQME29xx

CLG-24VDX415A9*
Replaced by C2LG36CE-DQME29xx
240V 3-phase Delta
50/60Hz
60A
IEC Blue 9hr 3P+G Plug,
10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
74.8 x 1.75 x 3.50 in. (1899 x 44 x 89 mm)
CSG-24VDV415A9
Replaced by C2SG36CE-DFME29xx

CLG-24VDV415A9*
Replaced by C2LG36CE-DFME29xx
240V 3-phase Delta
50/60Hz
50A
CS8365C Plug, 10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
74.8 x 1.75 x 3.50 in. (1899 x 44 x 89 mm)
CSG-24VYY411A9
Discontinued

CLG-24VYY411A9*
Discontinued
208V 3-phase  Wye
50/60  Hz
60A
IEC Blue 9hr 3P+N+G Plug,
10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
74.8 x 1.75 x 3.50 in. (1899 x 44 x 89 mm)

* CLG part numbers refer to the Expansion CDU
**Click here to view additional information on Power Cords and Cables

All models above have PIPS. PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.

 

Additional Features and Specifications

 

Agency Approvals

  • US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
  • FCC Class A, Part 15
  • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications and Security

  • 10/100 BaseT Ethernet
  • HTTP/HTTPS
  • SSLv3/TLSv1
  • SNMPv2
  • SSHv2
  • Telnet
  • LDAPS/LDAPv3
  • TACACS+
  • RADIUS
  • RS-232 (Serial)

 

Branch Circuit Protection

  • Compliant to UL 60950-1

Accessories

  • Optional Temperature & Humidity Probe
  • - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3m)

  • SPM (Sentry Power Manager) Appliance:
  • - Monitor and Manage multiple Sentry CDU's
    - Monitor and Manage all alarm conditions
    - Reporting and Trending
    - Group or Cluster outlets for reboot and power information
  • Environmental Monitor
  • - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.

 

1U SPM Appliance1U SPM 1U SPM

Expansion Module Model Numbers

  • CLG-24VDX415A9
  • CLG-24VDV415A9
  • CLG-24VYY411A9

 

Additional Benefits:

Pops Outlet

- POPS (Per Outlet Power Sensing)Monitor Current Load

(A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet at an accuracy of ±2%.

Pops Branch Circuit

- Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections> UL-489 rated circuit breakers

Pops Pips

- PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy kw/h, power capacity, reactance, and power capacity consumed using the network interface. See the aggregate current draw, in amps, locally using the onboard LED.

Pops Temperature

- Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Pops Mixed Outlets

- Mixed Outlets

This Switched CDU combines both IEC 60320/C13 and IEC 60320/C19 switched outlets within a single CDU. For rebooting non-responsive servers & network devices.