 Server Technology CWG-16H Series: Power Monitoring Single Phase 200-240VAC Switched PDU

All products here have been discontinued. Contact Bomara for a replacement

• Remote Power Management Power cycle individual power outlets
• Input Current Monitor Precise measurement
• IP Access & SecurityCWG-16H


The Switched CDU's combine remote configuration and management with power distribution, power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

Key Features:

  • High Density: Single power input feed; 16 outlets per 2U enclosure
  • High Power Distribution: 208V, or 230V power options; 16, 20, 30, 32-Amp input feed options
  • Remote Power Management: Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles
  • Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display. Remote verification via browser or serial screen.
  • IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, RADIUS, TACACS, RS-232 access
  • Traps & Alerts: Provide automated SNMP-based alarms and email alerts for power and environmental conditions
  • Environmental Monitoring: Each Switched CDU supports two temperature & humidity probes and reports conditions thru the Web interface
  • Add an Expansion Module: Connect the Switched Expansion CDU (CXG) to a Master unit (CWG) for power management of separate power circuits from a single IP address
  • Power-up Sequencing: Prevent an in-rush power overload
Additional Benefits:

Pops Outlet

- POPS (Per Outlet Power Sensing)Monitor Current Load

(A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet at an accuracy of ±2%.

Pops Branch Circuit

- Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections> UL-489 rated circuit breakers

Pops Input

- Input Current Monitoring

Exclusive Digital True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the CDU enclosure report the input current of the branch circuit.

Pops Temperature

- Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

 

Technical Specifications

Model
Available Input
Voltages
Amperage
Available Input
Cord**
Outlets
Dimensions
(L x W x D)
CWG-16H2A452
CXG-16H2A452*
208-240V
50/60Hz
20A
IEC 60320/C20
Power Inlet
(16) IEC 60320/C13
3.50 x 17.00 x 7.00 in. (89 x 432 x 178mm)
CWG-16H2C452
CXG-16H2C452*
208-240V
50/60Hz
30A
NEMA L6-30P Cordset, 10 ft (3m)
(16) IEC 60320/C13
3.50 x 17.00 x 7.00 in. (89 x 432 x 178mm)
CWG-16HEA452
CXG-16HEA452*
230V
50/60Hz
16A
IEC 60320/C20
Power Inlet
(16) IEC 60320/C13
3.50 x 17.00 x 7.00 in. (89 x 432 x 178mm)
CWG-16HEK452
CXG-16HEK452*
230V
50/60Hz
32A
IEC 60309
Cordset, 10 ft (3m)
(16) IEC 60320/C13
3.50 x 17.00 x 7.00 in. (89 x 432 x 178mm)
*CXG refers to the Expansion Module
**Click here to view additional information on Power Cords and Cables

 

Additional Features and Specifications

Agency Approvals

  • US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
  • European Union (TUVGS mark) to EN 60950-1:2001
  • FCC Class A, Part 15
  • CE
  • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications and Security

  • 10/100 BaseT Ethernet
  • HTTP/HTTPS > SSLv3/TLSv1
  • SNMPv2
  • SSHv2
  • Telnet
  • LDAPv3
  • LDAPS
  • TACACS+
  • RADIUS
  • RS-232 (Serial)


Branch Circuit Protection

  • Compliant to UL 60950-1

Expansion Module Model Numbers

  • CXG-16H2A452
  • CXG-16H2C452
  • CXG-16HEA452
  • CXG-16HEK452

Accessories

  • Optional Temperature & Humidity Probe
    -EMTH-1-1 Temperature & Humidity Probe, 10ft (3m)
  • Environmental Monitor - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
  • SPM (Sentry Power Manager) Appliance:
    - Monitor and Manage multiple Sentry CDU's
    - Monitor and Manage all alarm conditions
    - Reporting and Trending
    - Group or Cluster outlets for reboot and power information

Appliance Power Cord Options

  • PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
  • PTCORD-2 IEC 60320/C19 - Schuko 10ft (3m)
  • PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10ft (3m)
  • PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)
  • PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10ft (3m)
  • PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10ft (3m)
  • PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m)

 