Server Technology Products » Power Monitoring PDU » CWG-24V2/VE with PIPS

CWG-24V2/VE: POPS PDU Switched with PIPS

All products here have been discontinued. Contact Bomara for a replacement

• PIPS (Per Input Power Sensing)
• POPS (Per Outlet Power Sensing)

• Power monitoring per an individual outlet/ device
• Reboot a single or dual-power server with one command
• Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor

The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device. Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups. This Switched CDU has top entry for network, serial & environmental connections combined with a bottom power cord entry. Current monitors are easily inverted via the web GUI or serial interface. This provides flexibility when connecting Switched CDU's to overhead power or busways.

Key Features:

  • High Density: Single-power input feed; 24 outlets per enclosure (Qty 18 IEC C13 & 6 IEC C19 outlets)
  • Power Distribution: 208-240V, 20A and 30A; 230V 16A and 32A power input feed options
  • Input Current Monitor: Precisely measure the aggregate current draw (in amps) of the circuit. On-site verification of the input current with LED digital display. Remote verification via web browser or serial screen.
  • Network Power Management: Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles
  • IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS, RADIUS, and RS-232 access
  • SNMP Traps and Email alerts: Provide automated alerts for power and environmental conditions
  • Environmental Monitoring: Each Switched CDU supports two external temperature & humidity probes and reports conditions thru the user interface without the need for additional IP addresses
  • Add an Expansion Module: Daisy chain the Switched CDU Expansion Module (CXG) for power monitoring of separate power circuits from a single IP address
Additional Benefits: CWG 24 V2 VE With Pips

Pops Outlet

- POPS (Per Outlet Power Sensing)Monitor Current Load

(A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet at an accuracy of ±2%.

Pops Branch Circuit

- Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections> UL-489 rated circuit breakers

Pops Pips

- PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy kw/h, power capacity, reactance, and power capacity consumed using the network interface. See the aggregate current draw, in amps, locally using the onboard LED.

Pops Temperature

- Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Pops Mixed Outlets

- Mixed Outlets

This Switched CDU combines both IEC 60320/C13 and IEC 60320/C19 switched outlets within a single CDU. For rebooting non-responsive servers & network devices.

 

Technical Specifications

Model
Available Input
Voltages
Amperage
Available Input
Cord**
Outlets
Dimensions
(L x W x D)
CWG-24V2A415C1
CXG-24V2A415C1*
208-240V
50/60Hz
20A
IEC C20 Inlet, Bottom/Frt Entry
(18) IEC 60320/C13 (6) IEC 60320/C19
64.0 x 1.75 x 3.50 in. (1625 x 44 x 89 mm)
CWG-24V2C415C1
CXG-24V2C415C1*
208-240V
50/60Hz
30A
NEMA L6-30P Plug,
10'(3m), Bottom/Frt Cord
(18) IEC 60320/C13 (6) IEC 60320/C19
64.0 x 1.75 x 3.50 in. (1625 x 44 x 89 mm)
CWG-24VEA415C1
CXG-24VEA415C1*
230V
50/60Hz
16A
IEC C20 Inlet, Bottom/Frt Entry
(18) IEC 60320/C13 (6) IEC 60320/C19
64.0 x 1.75 x 3.50 in. (1625 x 44 x 89 mm)
CWG-24VEK415C1
CXG-24VEK415C1*
230V
50/60Hz
32A
IEC Blue  2P+G  Plug,
10'(3m), Bottom/Frt Cord
(18) IEC 60320/C13 (6) IEC 60320/C19
64.0 x 1.75 x 3.50 in. (1625 x 44 x 89 mm)

* CXG part numbers refer to the Expansion CDU
**Click here to view additional information on Power Cords and Cables

All models above have PIPS. PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.

 

Additional Features and Specifications

Agency Approvals

  • US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
  • European Union (TUVGS mark) to EN 60950-1:2001
  • FCC Class A, Part 15
  • CE
  • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications and Security

  • 10/100 BaseT Ethernet
  • HTTP/HTTPS
  • SSLv3/TLSv1
  • SNMPv2
  • SSHv2
  • Telnet
  • LDAPS/LDAPv3
  • TACACS+
  • RADIUS
  • RS-232 (Serial)

Branch Circuit Protection

  • Compliant to UL 60950-1

Expansion Module Model Numbers

  • CXG-24V2A415C1
  • CXG-24V2C415C1
  • CXG-24VEA415C1
  • CXG-24VEK415C1

Accessories

  • Optional Temperature & Humidity Probe
    - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3m)
  • Environmental Monitor
    - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
  • SPM (Sentry Power Manager) Appliance:

    Appliance Power Cord Options

    • PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
    • PTCORD-2 IEC 60320/C19 - Schuko 10ft (3m)
    • PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10ft (3m)
    • PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)
    • PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10ft (3m)
    • PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10ft (3m)
    • PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m)

    Power Cord Options

    • PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
    • PTCORD-2 IEC 60320/C19 - Schuko 10ft (3m)
    • PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10ft (3m)
    • PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)

     




  • Call Us: 1-978-452-2299
    First Name:
    Last Name:
    Company:
    Address:
    Mail Stop:
    City:
    State (if in US):
    Province/Region (if outside US):
    Country:
    ZIP (Postal) Code:
    E-mail:
    Telephone:
    Fax:
    Questions/Comments:
    Verification:

    View Full Site View Mobile Optimized