Server Technology Products » Power Monitoring PDU » CWG-24V4

 Server Technology POPS Switched CWG-24V4 400VAC 3 Phase 16/32A Busway 18xC13 & 6xC19 with PIPS:

All products here have been discontinued. Contact Bomara for a replacement
• PIPS (Per Input Power Sensing)
• POPS (Per Outlet Power Sensing)

• Power monitoring per an individual outlet/ device
• Reboot a single or dual-power server with one command
• Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor

CWG-24V4 400V 3PH 16/32A Busway with pipsThe Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device. Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups. This Switched CDU has top entry for network, serial & environmental connections combined with a bottom power cord entry. Current monitors are easily inverted via the web GUI or serial interface. This provides flexibility when connecting Switched CDU's to overhead power or busways.

Key Features

Technical Specifications

Model
Available Input
Voltages
Amperage
Available Input
Cord**
Outlets
Dimensions
(L x W x D)
CWG-23V4J458A1
CXG-24V4J458A1
230/400V 3-Phase Wye,
50/60Hz
16A
IEC Red 6hr 3P+N+G Plug,
10'(3m), Top Cord Entry
(18) IEC 60320/C13 (6) IEC 60320/C19
1753 x 44 x 89 mm
(69.0 x 1.75 x 3.50 in.)
CWG-23V4K458A1
CXG-24V4K458A1
230/400V 3-Phase Wye,
50/60Hz
32A
IEC Red 6hr 3P+N+G Plug,
10'(3m), Top Cord Entry
(18) IEC 60320/C13 (6) IEC 60320/C19
1753 x 44 x 89 mm
(69.0 x 1.75 x 3.50 in.)

* CXG part numbers refer to the Expansion CDU
**Click here to view additional information on Power Cords and Cables

All models above have PIPS. PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.

 

Additional Features and Specifications

Agency Approvals

  • European Union (TUVGS Mark) to EN 60950-1:2001
  • FCC Class A, Part 15
  • CE
  • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications and Security

  • 10/100 BaseT Ethernet
  • HTTP/HTTPS
  • SSLv3/TLSv1
  • SNMPv2 > SSHv2
  • Telnet
  • LDAPS/LDAPv3
  • TACACS+
  • RADIUS
  • RS-232 (Serial)

Expansion Module Model Numbers

  • CXG-24V4J458A1
  • CXG-24V4K458A1

Branch Circuit Protection

  • Compliant to UL 60950-1

Accessories

  • Optional Temperature & Humidity Probe
  • - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3m)

  • SPM (Sentry Power Manager) Appliance:
  • - Monitor and Manage multiple Sentry CDU's
    - Monitor and Manage all alarm conditions
    - Reporting and Trending
    - Group or Cluster outlets for reboot and power information
  • Environmental Monitor
  • - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
 

 

Additional Benefits:

Pops Outlet

- POPS (Per Outlet Power Sensing)Monitor Current Load

(A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet at an accuracy of ±2%.

Pops Branch Circuit

- Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections> UL-489 rated circuit breakers

Pops Pips

- PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy kw/h, power capacity, reactance, and power capacity consumed using the network interface. See the aggregate current draw, in amps, locally using the onboard LED.

Pops Temperature

- Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Pops Mixed Outlets

- Mixed Outlets

This Switched CDU combines both IEC 60320/C13 and IEC 60320/C19 switched outlets within a single CDU. For rebooting non-responsive servers & network devices.




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification:

View Full Site View Mobile Optimized