Servertech » Smart PDU » Smart CDU CS-2HD

Smart CDU CS-2HD

All parts on this page have been discontinued. Contact Bomara for a replacement.
3 Phase Modular -Servertech

The dual input, dual output Smart Power Monitor allows the ability to easily add input current load and power monitoring to any existing cabinet via an integral web based interface or through a serial connection.

This allows you to determine:
1) if there is available power to add additional devices to the cabinet.
2) if you are close to exceeding the circuit's capacity potentially leading to an over current protection device tripping and bringing down the input feed.
3) if each CDU is properly loaded to ensure redundancy when one of the two input feeds is lost.

This product is perfect for large storage solutions like SAN's where the CS-2HD can be added to existing installations to determine the power draw of these systems.
Note: In an A and B power input-feed configuration, each Cabinet Power Distribution Unit (CDU) should not be loaded to over 40% of the rated capacity to ensure that if one of the two power feeds is lost that the whole load can be supported by the remaining CDU.

Sentry  Cabinet PDU Specifications
Item # Input Voltages Rated
Amperage
Inputs Outlets Dimensions
(L x H x D)
CS-2HD
CS-2HD1B131Z1
Discontinued
120V 50/60 Hz 30A (2) NEMA L5-30P Input Cord Set, 10ft (2) NEMA L5-30R Output Cord Set, 3ft (0.91m) 1.75"x17.0"x7.0"
(44x432x178mm)
CS-2HD2C131Z1
Discontinued
CL-2HD2C131Z1
Discontinued
208-240V
50/60Hz
30A (2) NEMA L6-30P
Cord Set, 10ft (3.0m)
(2) NEMA L6-30R
Cord Set, 3ft (1.8m)
1.75"x17.0"x7.0"
(44x432x178mm)
CS-2HDEK131Z1
Discontinued
230V
50/60 Hz
32A (2) IEC 60309
Cord Set, 10ft (3.0m)
(2) IEC 60309
Cord Set, 3ft (1.8m)
1.75"x17.0"x7.0"
(44x432x178mm)
CS-2HD2I131Z1
Discontinued
Smart Power Monitor, 1U, (2) IEC 60309 250V 2P+G Blue 6hr 30A IP44 Input Cord Set, 10ft (3.0m), (2) IEC 60309 250V 2P+G Blue 6hr 30A IP44 Output Cord Set, 3ft (0.91m), 208V, 30A, (2) Temperature/Humidity Sensor Capable


Additional Features and Specifications

Standards
> cTUVus - UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS - EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)

 

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

1U Enclosure

A horizontal enclosure that occupies 1U horizontal rack space in the equipment cabinet. It typically mounts on the back of a 19 or 23 inch rack.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power Outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification:

View Full Site View Mobile Optimized