 Server Technology STV-3103D: Smart 3 Phase Delta PDU 208VAC L15-20P Input, (24) C13 & (6) C19 Output

All products here have been discontinued. Contact Bomara for a replacement

• Perfect for PUE Data Center reporting metrics
• Optional environmental monitoring
• Extended Temperature Range

STV-3103D (Master)
SEV-3103D (Expansion)





Inputs
Input Voltage: 208VAC 3 Phase
Input Phase: 3-Phase Delta (L-L)
Input Plug: NEMA L15-20P
Input Current: 20
Input Current Rated: 16
Outputs
Connector: (24) x IEC 60320/C13
North American Rating (C13): ≤ 12A @208V L-L (15A Peak)
   
Connector: (6) x IEC 60320/C19
North American Rating (C19): ≤ 16A @208V L-L (20A Peak)
   
Locking outlets provide high-retention even for non-locking cords.
Branch Circuit Protection
UL489 compliant 2-pole, 20A trip circuit breakers, three (3) branches, rating: ≤ 16A @208-240V
Physical
Dimensions: 70.1 (1781.0 mm) tall x 1.75 (45.0 mm) wide x 2.25 (58.0 mm) deep
Environmental
Operating Environment: 32°F to 149°F / 0°C to 65 °C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation
Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Quiescent / Unloaded Power Draw: <10W for all configurations
Communications & Security
10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU} Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certifications
North American: cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07 + A1:2011
EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
FCC Class A, Part 15
Measurement Accuracy
Input Measurement Accuracy: LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 0.1 kilowatt-hour resolution
Optional Accessories

EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
EMCU-1-1B Environmental Monitor adding:
   - Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
  - One (1) EMWS-1-1 water sensor port (probe sold separately)
  - Four (4) dry contact (NO/NC) monitoring points
  - One (1) 8-bit analog-to-digital converter (0 to 5VDC)

KIT-STEYE-01 or -10 provides access to key metrics through Bluetooth SPM (Sentry® Power Manager):
   - Monitor and manage multiple PDUs from a single point
   - Monitor and manage alarm conditions
   - Create reports and trends on stored data
   - Analyze power usage per phase
   - Optional appliance or virtual version
   - Vmware Ready2

Mounting Brackets:
   - Buttons (KIT-0020) included for tool-less mounting
   - Custom mounting options available. Contact Bomara Associates

Cable Retention Devices for non-locking cords:
   - Ezip
   - Cable Sleeve

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification:

View Full Site View Mobile Optimized