Eatons Products » ePDUs » STS 1400 (PULSTS1400R-1U)

 Eaton STS 1400 (PULSTS1400R-1U): Automatic Power Transfer Switch, Power redundancy and high-availability for your critical equipment


sts-1400

Features and Benefits

  • Provides redundant power source for any equipment

  • High-reliability solution: Pulsar STS includes both redundant relays and power circuit

 

  • Operates with any UPS or power source that has a sinewave output

  • Protection up to 1400 VA

  • 1U Rack space



Description:

The STS 1400 can be used as an automatic bypass for UPS <1,400 VA. It can be connected to up to 6 devices at the same time while saving the cost of expensive redundant power supplies. The STS 1400 has a power rating of 1,400 VA and output voltage at 120V.



  • Ordering Information
  • Overview
  • Diagram
  • Specifications



STS 1400 Ordering Information:

Part Numbers Description
PULSTS1400R-1U (66027) ePDU, 1U, Monitored, input 5-15P, output (6) 5-15R




STS 1400 Overview:

The Pulsar STS handles the automatic or manual transfer of your power loads between two independent sources designated as preferred or alternate. In the event of a failure, transfer is automatic and instantaneous.


Reliability and fault tolerance

With the Pulsar STS, you get more than just power source redundancy. With separate electronic control circuits for the preferred and alternate sources and with 2 relays, the Pulsar STS has added internal redundancy as well. That way, it continues to power your equipment even in the event of a fault.


Automatic bypass function


Pulsar STS can be used as an automatic bypass for the UPS. Hot swap function Pulsar STS lets you service manually one of the sources without interrupting the flow of power to your applications.


Communications


Pulsar STS 1400 includes multiple communication options:

• “STS COM” communication port Contact closure status signals for the STS COM port includes: Source S1 preferred, source S2 preferred, source S1 within tolerances, source S2 within tolerances, no fault STS and a common signal reference point.

• “META UPS COM” communication port This port allows you to connect directly to AS/400, Windows NT/2000, Unix, Linux, Netware or any Operating Systems that has a built-in UPS service. Communication with the redundant UPSs use the industry standard AS/400 contact closures for indication status and fault conditions.

• Software communication options Via the Protocol Interface (part # 66052), you can use Solution-Pac Wan or Personal Solution-Pac on your computer.

sts-1400-diagram





STS 1400 User interface and connections:

Pulsar STS, front view


sts-1400-pulsar-sts-front-view

     

Pulsar STS, rear view

sts-1400-pulsar-sts-rear-view





STS 1400 Specifications:

INPUT
Voltage 120V
Frequency 50/60hz
Plugs 2 * Nema 5-15, 6 ft cords
2 Circuit breakers 12 amps each
OUTPUT
Voltage 120V
Frequency 50/60hz
Receptacles 6 * Nema 5-15R
Circuit breakers 12 amps total
TRANSFER TIME
By source selector switch 4 ms
By automatic switch 7 ms
NO POINT OF FAILURE
Relay 2 redundant relays
Circuit path 2 redundant power paths
Circuit breaker on Input & Output
COMMUNICATION
UPS#1 port / UPS#2 port
STS COM / META UPS COM
DIMENSIONS
HxWxD 1.75 (1U)x19x9.8
WEIGHT
5lb
WARRANTY
2 years (parts and labor)

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized